Register here: http://gg.gg/nwxdx
Custom ’U’ Slot Insulation with sidewall step [1]
*Stator Slot Insulation Machine Home Depot
*Stator Slot Insulation Machine Manufacturers
*Stator Slot Insulation Machine Parts
*Stator Slot Insulation Paper Inserting Machine
*Stator Slot Insulation Machines
*Slot insulation machine This machine gang controls the main shaft and stator indexing shaft through PLC control system assembly. It conducts the insulation paper’s cutting, forming and inserting into the stator slots to all kinds of motor stators, to isolate the stator slots against motor windings.
*The insulation member 42 of the slot insulation is also inserted at this end face of the electric machine in an axial direction into the slots of the stator 10. Wire guides 52 are molded onto the insulation member 42 from which connecting pins 54 project in an axial direction that are used to connect the insulation member 42 to the flange, as.
*Slot cell forming machine WIND-150-IF. Product description: Form and cut the insulation paper for induction motor cell insulation such as pump,ceiling fan, compressor,hood motors,brushless permanent magnet motors. Machine can cut and bend insulation for the m.
*An extended form of the stator’s end insulation with injected slot shafts constitutes in the molded stator. In the last few years, injection molding has progressively been developed. It now allows to place the stator package into the injection mold and to facilitate the molding process.
Slot insulation is the common name for shielding material used for the rotor inside a power generator. The slot insulation process for electric motors provides a barrier between the copper wirings and the steel lamination for all stator, armature and rotor products.[2] This shielding material separates the rotor’s electrically conductive winding from its body.[3]
Horizontal Stator Insulation Paper Inserting Machine is suitable exclusively for large and medium-size motors, inserting insulation paper automatically from bottom of stator slot; automatic paper.Temperature ratings[edit]
Due to their operating environment, slot insulation must be capable of withstanding high temperatures. In the 1970s, slot insulation materials often had a Class F temperature rating (an operational range up to 155 °C).[4] Today, there are commercially available slot insulation materials with a Class H temperature rating (an operational range up to 180 °C)[5] Its composite of laminate materials, consisting of epoxy, aramid, and dielectric film, create its insulating properties.[6]Notes[edit]
*^Gerome Technologies U Slot Insulation
*^http://www.stator-systems.com/index.php?Itemid=63&category_id=1&option=com_virtuemart&page=shop.browse.
*^Payne, B. (2010) The Unsung Hero of Power Generation? The Power Generation Blog.
*^Gibney, J. GE Generators, An Overview.Archived 2011-01-02 at the Wayback Machine
*^PCT. Generator Rotor Slot Insulation.
*^Power and Composite Structures.References[edit]
*Payne, B. (2010) The Unsung Hero of Power Generation? The Power Generation Blog.
*Gerome Technologies Inc. Gerome Technologies U Slot Insulation
*Gibney, J. GE Generators, An Overview.
*PCT. Generator Rotor Slot Insulation.External links[edit]
Retrieved from ’https://en.wikipedia.org/w/index.php?title=Slot_insulation&oldid=959917996
Design of stator winding:
Stator winding is made up of former wound coils of high conductivity copper of diamond shape. These windings must be properly arranged such that the induced emf in all the phases of the coils must have the same magnitude and frequency. These emfs must have same wave shape and be displaced by 1200 to each other. Single or double layer windings may be used depending on the requirement. The three phase windings of the synchronous machines are always connected in star with neutral earthed. Star connection of windings eliminates the 3rd harmonics from the line emf.
Double layer winding: Stator windings of alternators are generally double layer lap windings either integral slot or fractional slot windings. Full pitched or short chorded windings may be employed. Following are the advantages and disadvantages of double layer windings.Advantages:
(i)Better waveform: by using short pitched coil
(ii)Saving in copper: Length of the overhang is reduced by using short pitched coils
(iii)Lower cost of coils: saving in copper leads to reduction in cost
(iv)Fractional slot windings: Only in double layer winding, leads to improvement in waveformDisadvantages:
(i)Difficulty in repair: difficult to repair lower layer coils
(ii)Difficulty in inserting the last coil: Difficulty in inserting the last coil of the windings
(iii)Higher Insulation: More insulation is required for double layer winding
(iv)Wider slot opening: increased air gap reluctance and noiseNumber of Slots:
The number of slots are to be properly selected because the number of slots affect the cost and performance of the machine. There are no rules for selecting the number of slots. But looking into the advantages and disadvantages of higher number of slots, suitable number of slots per pole per phase is selected. However the following points are to be considered for the selection of number of slots.
(a)Advantages:
(i)Reduced leakage reactance
(ii)Better cooling
(iii)Decreased tooth ripplesDisadvantages:
(i)Higher cost
(ii)Teeth becomes mechanically weak
(iii)Higher flux density in teeth
(b)Slot loading must be less than 1500 ac/slotStator Slot Insulation Machine Home Depot
(c)Slot pitch must be with in the following limitations
(i)Low voltage machines ≤ 3.5 cm
(ii)Medium voltage machines up to 6kV ≤ 5.5 cm
(iv)High voltage machines up to 15 kV ≤ 7.5 cm
Considering all the above points number of slots per pole phase for salient pole machines may be taken as 3 to 4 and for turbo alternators it may be selected as much higher of the order of 7 to 9 slots per pole per phase In case of fractional slot windings number of slots per pole per phase may be selected as fraction 3.5.Turns per phase:
Turns per phase can be calculated from emf equation of the alternator.
Induced emf Eph = 4.44 f Φ TphKw
Hence turns per phase Tph = Eph / 4.44 f ΦKw
Eph = induced emf per phase
Zph = no of conductors/phase in stator
Tph = no of turns/phase
kw = winding factor may assumed as 0.955
Conductor cross section: Area of cross section of stator conductors can be estimated from the statorcurrent per phase and suitably assumed value of current density for the stator windings.
Sectional area of the stator conductor as = Is/δs where δs is the current density in stator windings
Is is stator current per phase
A suitable value of current density has to be assumed considering the advantages and disadvantages.
Advantages of higher value of current density:
(i)reduction in cross section
(ii)reduction in weightStator Slot Insulation Machine Manufacturers
(iii)reduction in cost
Disadvantages of higher value of current density
(i)increase in resistance
(ii)increase in cu loss
(iii)increase in temperature rise
(iv)reduction in efficiency
Hence higher value is assumed for low voltage machines and small machines. Usual value of current density for stator windings is 3 to 5 amps/mm2.Stator coils:
Two types of coils are employed in the stator windings of alternators. They are single turn bar coils and multi turn coils. Comparisons of the two types of coils are as follows
(i)Multi turn coil winding allows greater flexibility in the choice of number of slots than single turn bar coils.
(ii)Multi turn coils are former wound or machine wound where as the single turn coils are hand made.
(iii)Bending of top coils is involved in multi turn coils where as such bends are not required in single turn coils.
(iv)Replacing of multi turn coils difficult compared to single turn coils.
(v)Machine made multi turn coils are cheaper than hand made single turn coils.
(vi)End connection of multi turn coils are easier than soldering of single turn coils.
(vii)Full transposition of the strands of the single turn coils are required to eliminate the eddy current loss.
(viii)Each turn of the multi turn winding is to be properly insulated thus increasing the amount of insulation and reducing the space available for the copper in the slot.
From the above discussion it can be concluded that multi turn coils are to be used to reduce the cost of the machine. In case of large generators where the stator current exceeds 1500 amps single turn coils are employed.Single turn bar windings:
The cross section of the conductors is quite large because of larger current. Hence in order to eliminate the eddy current loss in the conductors, stator conductors are to be stranded. Each slot of the stator conductor consists of two stranded conductors as shown in Fig XXX. The dimensions of individual strands are selected based on electrical considerations and the manufacturing requirements. Normally the width of the strands is assumed between 4 mm to 7 mm. The depth of the strands is limited based on the consideration of eddy current losses and hence it should not exceed 3mm. The various strand of the bar are transposed in such a way as to minimize the circulating current loss.

Multi turn coils:
Multi turn coils are former wound. These coils are made up of insulated high conductivity copper conductors. Mica paper tape insulations are provided for the portion of coils in the slot and varnished mica tape or cotton tape insulation is provide on the over hang portion. The thickness of insulation is decided based on the voltage rating of the machine. Multi turn coils are usually arranged in double layer windings in slots as shown in Fig XXX.

Dimensions of stator slot:
Width of the slot = slot pitch – tooth width
The flux density in the stator tooth should not exceed 1.8 to 2.0 Tesla. In salient pole alternators internal diameter is quite large and hence the flux density along the depth of the tooth does not vary appreciably. Hence width of the tooth may be estimated corresponding to the permissible flux density at the middle section of the tooth. The flux density should not exceed 1.8 Tesla. However in case of turbo alternators variation of flux density along the depth of the slot is appreciable and hence the width of the tooth may be estimated corresponding to the flux density at the top section of the tooth or the width of the tooth at the air gap. The flux density at this section should not exceed 1.8 Tesla.
For salient pole alternator:
Flux density at the middle section =
Flux / pole /( width of the tooth at the middle section x iron length x number of teeth per pole arc) Number of teeth per pole arc = pole arc/slot pitch
For turbo alternators:
Flux density at the top section =
Flux / pole /( width of the tooth at the top section x iron length x number of teeth per pole pitch) As the 2/3rd pole pitch is slotted the number of teeth per pole pitch = 2/3 x pole pitch/( slot pitch at top section) Slot width = slot pitch at the top section – tooth width at the top section.
Once the width of the slot is estimated the insulation required width wise and the space available for conductor width wise can be estimated.Stator Slot Insulation Machine Parts
Slot insulation width wise:
(i)Conductor insulation
(ii)Mica slot liner
(iii)Binding tape over the coil
(iv)Tolerance or clearance
Space available for the conductor width wise = width of the slot – insulation width wise
We have already calculated the area of cross section of the conductor. Using above data on space available for the conductor width wise depth of the conductor can be estimated. Now the depth of the slot may be estimated as follows.
Depth of the slot:
(i)Space occupied by the conductor = depth of each conductor x no. of conductor per slot
(ii)Conductor insulation
(iii)Mica slot liner
(iv)Mica or bituminous layers to separate the insulated conductors
(v)Coil separator between the layers
(vi)Wedge
(vii)Lip
(viii)Tolerance or clearanceMean length of the Turn:
The length of the mean turn depends on the following factorsStator Slot Insulation Paper Inserting Machine
(i)Gross length of the stator core: Each turn consists of two times the gross length of stator core.Stator Slot Insulation Machines
(ii)Pole pitch: The over hang portion of the coils depend upon the coil span which in turn depends upon the pole pitch.
(iii)Voltage of the machine: The insulated conductor coming out of the stator slot should have straight length beyond the stator core which depends upon the voltage rating of the machine.
(iv)Slot dimension: Length per turn depends on the average size of the slot.
Hence mean length of the turn in double layer windings of synchronous machines is estimated as follows.
lmt = 2l + 2.5 τp+ 5 kV + 15 cm
Register here: http://gg.gg/nwxdx

https://diarynote.indered.space

コメント

最新の日記 一覧

<<  2025年7月  >>
293012345
6789101112
13141516171819
20212223242526
272829303112

お気に入り日記の更新

テーマ別日記一覧

まだテーマがありません

この日記について

日記内を検索